WCT Solutions
Services · Infrastructure

Structured
Cabling
Solutions.

From initial site survey to certified handover — we design, install, test, and document copper cabling infrastructure that performs to standard and lasts.

Cat 5e · Cat 6 · Cat 6A · Cat 8 — certified with Fluke DSX-5000.

4

Cable categories

100%

Runs certified

TIA / ISO

Standards complied

10 Gbps

Max supported

Cable Standards

The Right Cable
for the Right Job.

We assess your bandwidth requirements, device density, PoE load, and growth plans before recommending a cable category. Installing the wrong standard costs more to fix than getting it right first time.

Cat 5e

1 Gbps · 100 MHz

100 m

VoIP phones, standard office workstations, PoE devices, legacy network upgrades.

Small offices
Retrofit projects
Budget-conscious builds

Cat 6

1 Gbps · 250 MHz

100 m

General office environments, meeting rooms, high-density workstation areas requiring improved noise margins.

Corporate offices
Meeting rooms
Mid-size deployments

Cat 6A

10 Gbps · 500 MHz

100 m

Data centres, hospitals, high-density Wi-Fi AP feeds, PoE++ (90W), and futureproofed enterprise networks.

Data centres
Healthcare
High-density Wi-Fi

Cat 8

40 Gbps · 2000 MHz

30 m

Top-of-rack data centre switch interconnects, high-speed server uplinks where short runs are acceptable.

Server rooms
ToR interconnects
Ultra-low latency
Scope of Work

Everything Included.
Nothing Missed.

Our structured cabling engagements cover the full lifecycle — from the first site walk to the final certification report. No scope gaps, no subcontracted surprises.

01

Site Survey & Cable Route Planning

We walk the site, measure routes, identify trunking paths, ceiling heights, and riser shafts before any design is committed to paper. Every cable route is documented.

02

Cabling Design & Port Schedule

Detailed CAD drawings showing outlet positions, patch panel ports, rack layout, and cable routes. Port schedules produced for every floor and zone.

03

Cable Installation & Routing

Cables are pulled through trunking, conduit, cable trays, and ceiling voids — neatly bundled, correctly separated from power, and supported at proper intervals.

04

Termination & Punch-Down

Cat 5e, 6, and 6A terminated to 110-style patch panels using proper punch-down tools. Every termination is checked for correct pin-out and twist preservation.

05

Patch Panel & Rack Dressing

Patch panels front-loaded into racks, cables laced and velcroed at the rear, 1U blanking between panels. Clean, structured, and maintainable.

06

Outlet & Face Plate Installation

Flush wall plates, floor boxes, surface-mount outlets, and desk grommets — all installed to specified positions, labelled, and keystoned to the correct port.

07

Labelling & Asset Tagging

Every cable, patch panel port, face plate outlet, and rack unit labelled to ANSI/TIA-606 — machine-printed, durable, and consistent throughout the installation.

08

Testing & Certification

All copper links tested with the Fluke Networks DSX-5000 to the relevant TIA or ISO standard. Pass/fail for every parameter — wiremap, length, insertion loss, NEXT, FEXT, return loss.

09

As-Built Documentation & Reports

Complete as-built drawings updated to reflect final installed positions, plus full LinkWare test reports — every run, every result, delivered digitally.

10

Warranty & Handover

Installation documentation package, port-to-outlet schedule, and where applicable, a system warranty registered with the cable manufacturer.

Environments

Every Environment.
Properly Cabled.

We've installed structured cabling in offices, hospitals, warehouses, schools, hotels, and retail spaces. Each environment has different constraints — we know them all.

Corporate Offices

Open-plan workstation feeds, meeting room AV drops, reception, server room backbone — designed for growth and easy MAC work.

What we cable in this environment

Workstation outlets
Meeting room AV & UC
Reception & common areas
Server room / IDF cabling
Certified Testing

Every Run Tested.
Every Result Documented.

We certify 100% of installed links using the Fluke Networks DSX-5000 — the industry benchmark for copper cable certification. Tests cover:

Wiremap
Cable length
Insertion loss
Return loss
NEXT
PS-NEXT
FEXT
PS-ACRF

Test output per link

Wiremap
All pairs correctPASS
Length
42.3 mPASS
Insertion Loss
8.4 dB @ 500 MHzPASS
NEXT (worst pair)
3.2 dB marginPASS
Return Loss
4.1 dB marginPASS

Sample — all results delivered via LinkWare certification report

Why WCT

Cabling Done
Properly.

Bad cabling causes intermittent faults, failed upgrades, and warranty headaches for years. We install it right — and certify it to prove it.

Talk to Our Team

Certified Every Time

We certify every single cable run with the Fluke DSX-5000. Not a sample — every run. You get a LinkWare report showing pass/fail for each parameter.

Standards Compliance

All work is designed and installed to TIA-568, ISO/IEC 11801, and ANSI/TIA-606 labelling standards — meeting manufacturer warranty requirements.

Clean, Engineered Installations

We take pride in the quality of our physical workmanship. Neat cable management, consistent dressing, and racks that look as good in 10 years as day one.

Full Documentation

As-built drawings, port schedules, test reports, and warranty documents delivered at handover — not chased for weeks after the job is done.

Start Your Project

Need Cabling
Done Right?

Tell us your site, your port count, and your timeline. We'll scope the job, recommend the right cable category, and deliver a fixed-price proposal — with certification included.