WCT Solutions
Services · Infrastructure

Turnkey
Data Center
Solutions.

From blank floor plan to fully operational data centre — we design, build, cable, cool, secure, and commission the entire facility under one contract.

One team. One accountability. Zero gaps between disciplines.

12

Disciplines covered

6

Phase delivery model

99.9%

Uptime target

1

Point of contact

What Turnkey Means

We Handle
Everything.

Most data centre projects involve half a dozen separate contractors — a civils firm, an MEP engineer, a cabling company, a network integrator, a security installer. Each with their own schedule, their own interfaces, and their own excuses when things don't align.

We eliminate that complexity. WCT delivers the complete facility under one project plan, one commercial agreement, and one team responsible from concrete to commissioning.

Civil works, raised flooring & partition walls
Power: UPS, PDUs, ATS & generator interface
Precision cooling & hot/cold aisle containment
Structured cabling, fiber backbone & rack systems
Network infrastructure, access control & CCTV
Fire suppression, DCIM & full commissioning

Disciplines Covered

Civil Works
Electrical
Mechanical
Cabling
Networking
Security
Surveillance
Fire Systems
Monitoring
Racks & Infra
Scope of Work

12 Disciplines.
One Delivery.

Every component of your data centre — designed, procured, installed, and certified by our team under a single project plan.

Phase 01

Site Assessment & Design

Full feasibility study, load analysis, floor plan, and engineering drawings before a single cable is pulled.

Phase 01

Server Room Construction

Raised flooring, partition walls, ceiling tiles, cable trays, and fire-rated penetrations built to spec.

Phase 02

Precision Cooling

CRAC and CRAH unit selection, hot/cold aisle containment, and airflow modelling for optimal PUE.

Phase 02

UPS & Power Distribution

N+1 UPS configuration, PDUs, automatic transfer switches, and generator integration for zero downtime.

Phase 03

Structured Cabling

Cat 6A copper and OM4/OS2 fiber backbone — installed, terminated, and certified with Fluke DSX-5000.

Phase 03

Rack Systems & Management

Rack layout, blanking panels, cable management arms, overhead trays, and labelling to ANSI/TIA standards.

Phase 03

Network Infrastructure

Core/distribution/access layer switching, firewall deployment, and structured patch panel configuration.

Phase 04

Access Control

Biometric and card-based entry for server room zones with audit logging and multi-factor authentication.

Phase 04

CCTV & Surveillance

IP camera coverage across entry points, aisles, and perimeter — integrated with NVR and remote monitoring.

Phase 04

Fire Suppression

Clean agent (FM-200 / Novec 1230) systems designed to protect equipment without water damage.

Phase 05

Remote Monitoring (DCIM)

Real-time dashboards for temperature, humidity, power draw, and uptime — with alerting and reporting.

Phase 05

Testing, Commissioning & Handover

End-to-end load testing, failover verification, full as-built documentation, and staff training.

How We Deliver

Six Phases.
Zero Surprises.

Phase 01

Consultation & Survey

We assess your site, understand your compute requirements, redundancy needs, and compliance constraints before any design work begins.

Phase 02

Design & Engineering

Detailed architectural, electrical, and mechanical drawings. Load calculations, cooling models, and single-line diagrams reviewed and signed off.

Phase 03

Procurement

We source hardware and materials from approved vendors — avoiding grey market components and ensuring full warranty coverage.

Phase 04

Build & Installation

Our certified team executes the full build: civil works, power, cooling, cabling, racks, and security — under one project plan.

Phase 05

Testing & Commissioning

Comprehensive functional testing including failover drills, cooling stress tests, cable certification, and UPS discharge tests.

Phase 06

Handover & Support

Full as-built documentation, equipment registers, test reports, and a structured knowledge transfer to your operations team.

Why WCT

Built Different.
Delivered
Differently.

There are many companies who will quote you a data centre. There are fewer who have built dozens, who know where projects fail, and who have the teams, partnerships, and processes to prevent it.

Discuss Your Project

Single Point of Accountability

One contract, one project manager, one team responsible for every discipline — from civils to commissioning. No finger-pointing between contractors.

Certified Engineers

Our engineers hold industry certifications across data center design, structured cabling, electrical systems, and network infrastructure.

Manufacturer Partnerships

We work directly with Schneider Electric, APC, Panduit, Fluke Networks, and other tier-1 vendors — giving you access to authorised products and support.

Proven Delivery Track Record

Dozens of data centre builds and server room fit-outs across commercial, healthcare, government, and industrial sectors.

Post-Handover Support

We don't disappear after handover. Maintenance contracts, remote monitoring, and rapid-response SLAs available from day one.

Fully Documented Delivery

Every project is closed with as-built drawings, equipment data sheets, test certificates, and a complete O&M manual — audit ready.

Ready to Build

Your Data Centre.
Built Right. First Time.

Tell us about your project — capacity requirements, timeline, and site constraints. We'll come back with a scoped proposal, not a generic brochure.