Fiber Optic
Networks.
Solutions.
From site survey to certified handover — we install, splice, and OTDR-certify singlemode and multimode fiber infrastructure that performs to standard and lasts.
OS1 · OS2 · OM3 · OM4 · OM5 — certified with Fluke OptiFiber Pro.
OS1/OS2 + OM3–OM5
Fiber standards
100%
OTDR certified
400G capable
Max bandwidth
IEC 61300-3-35
End-face standard
The Right Fiber
for the Right Link.
Singlemode or multimode, indoor or outdoor — the choice of fiber type, core count, and connector determines whether your link meets its loss budget now and remains fit for purpose as speeds increase.
OS1
Singlemode · 9/125µm
Indoor tight-buffered singlemode fiber for riser and campus inter-floor applications. Low-loss, long-reach performance within buildings.
OS2
Singlemode · 9/125µm
Loose-tube outdoor/OSP singlemode fiber engineered for inter-building and underground campus links requiring long reach and environmental resilience.
OM3
Multimode · 50/125µm
Laser-optimised multimode fiber suitable for 10G data centre horizontal and server room link applications at moderate distances.
OM4 / OM5
Multimode · 50/125µm
OM4 delivers 10G to 550 m and 100G to 150 m. OM5 wideband multimode extends to 100G+ via SWDM, ideal for ultra-high-density hyperscale data centres.
LC · SC · MPO/MTP · ST
LC
Lucent Connector
The dominant data centre and enterprise connector. Small form factor, push-pull latch. Used on SFP/SFP+ transceivers, patch panels, and high-density installations.
SC
Subscriber Connector
Square push-pull connector with excellent repeatability. Common in older installations, telco, and outside plant termination. Still widely specified.
MPO/MTP
Multi-Fibre Push-On
Multi-fibre connector carrying 8, 12, or 24 fibres in a single push-fit body. Used in high-density trunk cable systems, pre-terminated backbone, and 40G/100G+ parallel optics.
ST
Straight Tip
Bayonet-style connector used in legacy multimode installations, campus environments, and some industrial applications. Robust, but being replaced by LC/SC in new installs.
Everything Included.
Nothing Missed.
Our fiber optic engagements cover the complete lifecycle — from the first site walk to the final OTDR certification report. No scope gaps, no corners cut.
Site Survey & Route Planning
Underground routes, riser paths, and duct availability assessed on-site. Every proposed fiber route is walked, measured, and documented before design begins.
Fiber Design & Specification
Core count, fiber type, connector selection, and loss budget calculation produced for every link. Design accounts for splices, connectors, bend losses, and future headroom.
Cable Installation
Internal installation via trunking and conduit. Underground via duct or direct-burial. Aerial span where required. All routes correctly supported, labelled, and documented.
Fusion Splicing
Arc-fusion splicing to less than 0.1 dB per splice. Every splice is heat-sleeved and properly housed in a splice tray within a suitable enclosure or termination point.
Mechanical Termination
Field-terminated connectors installed where fusion splicing is not practical — using pre-polished ferrule termination kits for a clean, reliable end-face every time.
End-Face Inspection
Every connector end-face cleaned and inspected to IEC 61300-3-35 before testing. Contaminated connectors are the number one cause of fiber link failure — we eliminate that risk.
OTDR Testing
Bi-directional OTDR traces captured with the Fluke Networks OptiFiber Pro. Every event — connector, splice, bend — is identified, logged, and measured.
Optical Loss Testing
Insertion loss measured with a calibrated light source and power meter. Results validated against TIA/ISO loss budgets for the specific link type and length.
Certification Reports
Full OTDR trace files and pass/fail certification reports generated via Fluke LinkWare for every link. Delivered digitally at project handover.
As-Built Documentation
Fiber schedule, splice records, route drawings, and termination schedules compiled and delivered at handover. Complete record of the installed infrastructure.
Every Environment.
Properly Fibered.
From underground campus runs to ultra-high-density data centres — we've installed fiber in demanding environments and understand the constraints, standards, and workmanship that each one requires.
Campus Backbones
Inter-building OS2 singlemode for long-reach campus links, riser backbone cabling between floors, and MDF to IDF distribution fiber — the backbone your network depends on.
What we install in this environment
Every Link Traced.
Every Event Logged.
We use the Fluke Networks OptiFiber Pro OTDR — the industry standard for fiber certification. Every link is tested bi-directionally, with results averaged per TIA and ISO methodology.
OTDR event log — sample link
| Event | Description | Distance | Loss | Result |
|---|---|---|---|---|
| Event 1 | Launch connector | 0 m | 0.08 dB | PASS |
| Event 2 | Fusion splice | 245 m | 0.04 dB | PASS |
| Event 3 | Fusion splice | 612 m | 0.06 dB | PASS |
| Event 4 | End connector | — | 0.09 dB | PASS |
Total link loss
Budget: 1.5 dB
0.27 dB
PASSSample — tested bi-directionally, results averaged per TIA/ISO
Fiber Done
Properly.
A fiber link is only as good as its weakest splice, dirtiest connector, or missing test. We eliminate all three — and prove it with documentation you can rely on.
Talk to Our TeamFusion-Spliced Quality
Less than 0.1 dB per splice, every time. Every splice is heat-sleeved and properly housed in a splice tray — not left loose in an enclosure.
Bi-Directional Testing
We test every link in both directions and average the results — the correct method per TIA and ISO standards, not a shortcut.
End-Face Inspection
Every connector is cleaned and inspected against IEC 61300-3-35 before testing. Dirty connectors are the number one failure cause in fiber — we eliminate the risk.
Complete Handover Pack
OTDR traces, insertion loss reports, splice records, and as-built drawings — all delivered at handover, not chased for weeks afterwards.
Fiber That Performs.
Certified to Prove It.
Tell us your site, your routes, and your bandwidth requirements. We'll scope the job, specify the right fiber type, and deliver a fixed-price proposal — with OTDR certification included as standard.